Precise surveying

Is telecentricity really the solution for precise optical measurement?

To answer this question and better understand the various options offered by our calculators, we provide some basic explanations regarding optical metrology here.

When we talk about high-precision measurement, it typically involves measuring how wide and/or high an object is. In addition, object features such as bores, holes, individual components, adhesive beads, or similar elements are to be measured in width or height.

Or, for example, you may want to know where these objects are located relative to the edges of the overall object; this can include information about the distance to the edge or the rotational position.

Human Eye vs. Camera Technology

The human eye usually recognizes the edges of an object or feature immediately. For machine vision, however, this is not always as clear, as it is subject to many physical limits and conditions.

When a machine vision system examines the edges of an object, we refer to them as "edges." These edges are transitions from light to dark, or vice versa . The direction of the transition can also change "across the edge." These transitions are extracted using so-called edge tools . It's important to remember that the image is projected via the optics onto a sensor, which has a finite number of pixels (individual light-sensitive elements of a sensor) . Typically, the accuracy that describes precisely where the transition from light to dark occurred is limited to the number of pixels onto which the edge is mapped. Additionally, there's the problem that with a sensor, the transition from black to white cannot be mapped from one pixel to its neighbor. Some light from the dark side always falls onto the pixel that is actually measuring the light area, and vice versa. To represent an edge, at least two, ideally three, pixels are needed across which the edge can be measured.

Problem Sampling Theorem

Merely for the sake of completeness, the classic physical problem known as the Nyquist sampling theorem should be mentioned here, which states that every signal must be sampled at twice the frequency of the resolution. This fact represents the limit of optical resolution.

Therefore, when our calculator asks for the width of the measurement field, we want to know the size of the image area to be measured and which part of the image is projected onto the wide side of the sensor. This tells us how many pixels we have available, for example, per millimeter.

The next question that needs to be answered concerns resolution: What is the smallest defect or smallest object you want to see, and how large or wide is it? Based on this information and the number of pixels per mm, we can calculate the required resolution or, conversely, define the necessary number of camera pixels and other required optical components based on your specifications.

Pixel-accurate Measurement vs. Subpixel-accurate Measurement

If the edges of a measured object are sharp and the system setup dictates how the data is generated, these edges can also be measured to obtain valid results "within" a single pixel. In this case, you can exceed the actual pixel/mm resolution by a factor of up to 10 and measure "between the pixels." This mathematical increase in resolution is called subpixeling. However, caution is advised with this technique because it does not use real data, but rather interpolation, and you must ask yourself whether sub-decimal results make sense and represent actual measured values.

Since we can only apply subpixel technology when edges have a specific texture and the system meets certain prerequisites, we have defined several "tasks" or "imaging situations" in our calculators.

Backlight Measurement

The simplest case of optical metrology is the use of the so-called backlight setup. Here, the object to be measured is positioned between a light source and the camera, ideally at some distance from the light source. The camera essentially looks "into the light," and the object is seen only as a silhouette—much like the moon (object) appears dark when it passes between the observer (camera) and the sun (light source) during a solar eclipse.

In this case, the light rays strike the object from "infinity" (i.e., very parallel) or graze the object and hit the sensor. Wherever the object is "hit," the pixels in the image turn black/dark, while everything else remains white/light. The transition, or edge, can now be measured very accurately, even down to the subpixel level.

However, it must be clear that only the outermost contour can be measured. All elements located on the object remain black to the camera; meaning that if features on the surface of an object need to be measured, the backlight setup is unsuitable.

For high measurement accuracy, parallel light propagation is very important. In practical metrology, this must first be generated by the lighting and supported by the optics, such as telecentric optics. Therefore, our calculators distinguish between telecentric and entocentric imaging technology.

Detailed information on these imaging technologies can be found in our whitepaper
“Measurement Accuracy is Key: Telecentric Measurement vs. Entocentric Measurement“

Coin Stamping Example

Let's take the example of a coin stamping. Here, the user assumes that a coin has an embossed edge that is at a 90° angle to the surface and is considered very sharp. However, this is not true, because the coin has a slight bulge, and this bulge is what gets measured.

Worse yet, during stamping, some metal may be displaced and stick out, perhaps even "at the very bottom" of the coin. In this case, the outermost tip of the displaced metal would be measured rather than the actual edge visible "from above." Therefore, to understand the results, it is very important to know exactly where the measurement is being taken. In the described case, exactly this protruding burr can, of course, also be a defect that needs to be detected and measured.

However, the conditions and limitations explained so far are only the "simple" physical constraints. For high-precision metrology, meaning measurements in the range of 1–2 µm and below, additional physical properties such as must be taken into account

  • Vibrations (which can be countered, for example, with short exposure times or heavy mechanics)
  • Diffraction at the slit (i.e., the property of object edges or optical settings)
  • Wavelength of the light (whether using only one color or possibly infrared, where the wavelength itself is already 1 µm)

must be taken into account. However, detailed explanations of this would completely go beyond the scope, which is already broad here.

Measurement in incident light

If we want to measure elements on an object, we must work in incident light. In this lighting situation, further problems often arise regarding light direction and edge properties. To explain these better, we need to look into a few more properties of light.

When light hits an object, it is normally absorbed to some extent by the object, meaning that part of the light remains "in the material" as energy, but above all it is reflected. We take advantage of this in machine vision. Reflection follows the simple law of angle of incidence = angle of reflection. So far, so simple – but what is difficult to comprehend yet important for understanding optical metrology and machine vision in general is this: The camera (and incidentally also the eye) does not see the objects. It only sees the light reflected by the object. Therefore, we must control how the light is directed onto the object so that its reflection ends up in the camera or the optics. In addition, we must consider how the object is structured, i.e., where the light rays strike and at what angle they are thrown back. This is where the measurement object comes into play. However, if the edge is slightly rounded, as is the case with most real objects, the light is reflected across all angles and only a part of it lands on the sensor. Yet this is usually neither the beginning nor the end of the curvature, but somewhere in between.

If an object to be measured is manufactured identically, which is actually a basic requirement of series production, and has only a slight rounding, the edge can be measured relatively precisely at the same location in a repeatable light and position situation.

This is the situation where we speak of "clear edges" in our calculator. Clear edges are high-contrast edges to us, but can also be easily recognizable transitions from one material/surface to another, or from one color to another. In both cases, the necessary contrast is usually created by different absorption properties.

In contrast, we speak of "unclear edges" when object borders have low contrast, or large or changing roundings, or are made of different materials / surfaces with similarly strong absorption properties and therefore too little light is reflected onto the sensor. In principle, we can also measure "unclear edges," but this requires a few tricks and more effort and usually does not deliver the same accuracy as "clear edges."

Validation of an optical measuring system

As the last fundamental point of (optical) metrology, we would like to address the validation of the measuring system and its comparability with other measurement methods.

Let's return to the situation of the "clear edge" with a small rounding and the example of coin measurement. Let's assume the coin is bent at a 90° angle at the transition from the surface to the edge, and the radius of the bend is small. In this case, we have difficulty comparing the measurement results of optical metrology with those of a mechanical caliper, which simply measures the outermost metal displacement on one side and the outermost metal displacement on the other side.

In incident light, we measure the point with the highest reflection on the rounded bend with the corresponding point on the opposite side of the coin. These two measurements (mechanical / optical in incident light) cannot match because they took place at different positions. For an exact match, one would have to have the rounding measured at great expense in a laboratory using a tactile measuring system to find out exactly where the point with the highest reflection is in reality, and correct a few other factors, such as the fact that the tactile measuring system measures the rough surface only on the "material peaks" while machine vision reaches down into the "valleys" and averages them out.

This not only sounds complicated, it is. There are procedures for this such as MSA (Measurement System Analysis), known in German as Messsystemanalyse or Messmittel-Fähigkeitsanalyse or Prüfmittel-Fähigkeitsanalyse, which confirm a measurement equipment capability to the user that can withstand audits.

If you would like to know more about this topic, we refer you to our whitepaper
“Measurement Equipment Capability Analysis for Optical Measuring Systems”