More than just presence detection
Of course, transmitted light is frequently used for simple tasks, such as presence detection or position determination. And it is exceptionally well-suited for that.
However, transmitted light truly shows its strength in measurement tasks. When edges need to be detected with absolute reliability and precision, there is hardly any alternative. Therefore, whenever possible, transmitted light is our first choice for projects requiring high-precision geometric measurements.
The right lens. The deciding factor.
Especially when an object plane is not completely flat, we frequently use telecentric lenses. This is because telecentricity eliminates the perspective errors that are unavoidable with standard lenses. Edges appear consistent across the entire field of view without distortion. In addition, it helps to capture edges more precisely because the light rays run parallel.

However, there is one point to keep in mind that many underestimate. Regardless of the chosen lens, its resolution capability must be appropriate. It is not enough to consider only the sensor resolution. The lens must also be able to optically separate the structures to be measured cleanly.
When the sensor, optics, and lighting are correctly matched to one another—and this is consistently impressive—measurement capabilities can be achieved that are two to three times better than the nominal pixels-per-millimeter resolution.
Practical tests. What we have learned.
In our laboratory, we use calibration plates etched with an accuracy of 0.15 µm for system analyses. In doing so, we follow a fundamental rule: the calibration object should be at least ten times more accurate than the target measurement capability, and ideally even twenty times.
One point that surprises many of our clients is the importance of exposure. Measurement objects must not be overexposed. Our experience shows that slightly darker images, which may look unusual to the eye, generally deliver more stable and reproducible measurement results.
Our methodology is simple yet consistent. We measure all known distances between the calibration points across the entire field of view and repeat these measurements multiple times. This gives us statistically reliable statements about the actual system performance.

The numbers speak for themselves. Comparison of transmitted light concepts.
This approach makes it possible to quantify very precisely what different transmitted light variants can achieve.
Our preferred solution is directed transmitted light. A telecentric transmitted light source improves measurement accuracy by an additional 0.3 µm compared to a directed transmitted light plate. If you need this accuracy, it is ideal. If not, you can save yourself the extra cost.
Diffuse transmitted light plates perform the worst, especially when positioned very close to the object. Edge sharpness decreases significantly, which is immediately reflected in poorer measurement accuracy.
Conclusion
Transmitted light is not a standard solution that you simply plug in, but rather a high-precision measuring tool,
requiring clean design and a thorough understanding. However, when implemented correctly, the results are significantly better than what you would expect from pixel resolution alone.
In industrial machine vision, the rule is clear.
When precision truly matters, transmitted light is often the only viable way forward.